Multi-Parameter Patient Monitor · VSM Series · Continuous Monitoring

PCB-VSM-10

PCB-VSM10 Multi-Parameter Patient Monitor
About the PCB-VSM10

Built for continuous patient monitoring.

The PCB-VSM10 is a Multi-Parameter Patient Monitor designed to continuously and accurately monitor adult, pediatric, and neonatal patients across a wide range of clinical environments.

Equipped with a 10.1″ color touchscreen (1024×600) and 7 selectable display interfaces, the system delivers clear visualization of ECG, Heart Rate, NIBP, SpO₂, Pulse Rate, Respiration, and Temperature — the seven core vital signs every general ward and post-operative unit needs.

Built for continuity, the integrated Li-ion battery ensures over 3 hours of operation, with low-battery alarm and rapid-charge protection. CF-type defibrillation-proof applied parts and IPX1 protection make it safe for use in OR, ICU, ED and recovery.

Compact, fanless, and ready for daily clinical use — the PCB-VSM10 is engineered to perform when continuous monitoring matters.

Configuration · Function · Specifications

Engineered for clinical reliability.

10.1″ touch monitor with full vital-sign coverage, integrated Li-ion battery and CF-type defibrillation-proof inputs for safe continuous monitoring.

Display

10.1″ color LED touchscreen, 1024×600 resolution
7 layouts: Standard, Big Font, OxyCRG, Trend, Vital Sign, Holistic Waveform, Multi-Bed

Measurements

ECG (3 / 5 / 12-lead), HR, NIBP
SpO₂, PR, Respiration, dual-channel TEMP

Battery & Power

Li-ion 14.6 V / 2500 mAh, ≥180 min
AC 100–240 V, 50/60 Hz

Data Storage & Connectivity

Trend data 1200/2400/7200 hrs · Holistic waveform 48 hrs · NIBP records up to 5,000 · Alarm events up to 5,000 · Ethernet RJ45, Wi-Fi (optional), HDMI, USB 2.0×2, HL7 protocol

Alarm System

Three-tier priority (High / Medium / Low) · Tri-color visual light · Adjustable volume 1–10 · Auto limit, latch and nurse-call support

Physical · Environment · Compliance

Dimensions ≤ 260 × 157 × 212.5 mm · Weight ≤ 4.70 kg · Storage ≥ 8 GB · Operating 5–40 °C, 15–85% RH, 57–106 kPa · Class I / Internal Power · CF-type defib-proof · IPX1 · Patient leakage < 40 µA · Standards: GB 9706.227-2021 (ECG), YY 9706.230-2023 (NIBP), YY 9706.261-2023 (SpO₂), YY 9706.256-2023 (TEMP)

PCB-VSM10 connections side view
Touch interface & connectivity

Designed for fast clinical decisions

Large 10.1″ touchscreen with high-contrast layouts, configurable trends and multi-bed view — built around the workflow of busy wards and post-operative units.

  • 7 display interfaces (Standard, Big Font, OxyCRG, Trend, Vital, Holistic, Multi-Bed)
  • Multi-bed view over Ethernet / Wi-Fi
  • HL7 transmission of parameters + waveform
  • HDMI output for big-screen mirroring
ECG / Heart Rate
  • Leads: 3 / 5 / 12-lead (AHA & IEC)
  • HR range Adult: 15–300 bpm
  • HR Pediatric/Neonatal: 15–350 bpm
  • Accuracy: ±1 bpm or ±1%
  • Freq. response Diagnostic: 0.10–150 Hz
  • Freq. response Monitor: 0.67–40 Hz
  • CMRR Diagnostic: >100 dB
  • CMRR Monitor/Surgical: >110 dB
  • Defib recovery: <3 s
  • Pacemaker: detection & suppression
  • iMAC algorithm: ST & arrhythmia
NIBP & SpO₂
  • NIBP method: Oscillometric (YY 9706.230)
  • Systolic: 30–260 mmHg
  • Diastolic: 10–220 mmHg
  • MAP: 20–235 mmHg
  • Static accuracy: ±3 mmHg
  • Modes: Manual / Auto / Continuous / Sequential
  • Over-pressure protection: 290 mmHg
  • SpO₂ range: 0–100% (res. 1%)
  • Accuracy 70–100%: ≤ ±2%
  • PR from SpO₂: 30–250 bpm
  • PI: 0.03–20% · FASP algorithm
Respiration & Temperature
  • RESP method: Impedance pneumography
  • Adult RR: 0–120 rpm
  • Pediatric/Neonatal RR: 0–150 rpm
  • Accuracy 8–150 rpm: ±2 rpm or ±2%
  • Apnea delay: 10–40 s
  • TEMP method: Thermistor, dual channel
  • Sites: Surface, Ax, Ear, Oral, Rectal, T1, T2
  • Range: 25–45 °C (±0.2 °C)
  • Extended: 0–24.9 / 45.1–50 °C (±0.4 °C)
  • Resolution: 0.1 °C
  • ΔT: display and alarm
Why VSM10

Built for continuous care.

🩺

7 vital signs

ECG, HR, NIBP, SpO₂, PR, RR and TEMP — everything a general ward, OR or ICU needs in a single compact monitor.

🔋

Li-ion battery

14.6 V / 2500 mAh battery for ≥3 hours of continuous monitoring during transport or power outages.

👶

Adult, Pediatric & Neonatal

Configurable measurement ranges and CF-type defibrillation-proof inputs across all patient categories.

Used across clinical environments

OR / SurgicalPost-Operative RecoveryICU / CCUEmergency DepartmentGeneral Ward
Certified quality

Manufactured under ISO 13485

ISO 13485 is the international standard for medical device quality management. PCB Medical equipment is built to international standards for patient monitoring.

CEISO 9001ISO 13485
📄

Product brochure

Complete PCB-VSM-10 datasheet in PDF, ready to print or send to your client.

Download brochure (PDF) ↓

PDF format · English · 4 pages
WhatsApp