PCB-FL-01

SKU: PCB-FL-01-BR Category:
Unidade de Fototerapia Neonatal · LED · 3 Intensidades Ajustáveis · Silenciosa Sem Ventilador · CE / ISO 13485

PCB-FL-01

PCB-FL-01 Infant Phototherapy Unit
Sobre o PCB-FL-01

Fototerapia LED para tratamento seguro e silencioso de icterícia.

The PCB-FL-01 Infant Phototherapy Unit is a mobile LED phototherapy lamp designed for the treatment of neonatal jaundice (hyperbilirubinemia). It uses a bank of 17 blue LED bulbs (420–490 nm) at the clinically effective wavelength, with a 50,000-hour service life — replacing traditional fluorescent tubes that lose intensity quickly and need frequent service.

Irradiance intensity is adjustable in 3 grades (Low / Medium / High) so the clinical team can match the dose to the bilirubin level. A built-in LCD shows therapy time + integral time separately, with both count-up and count-down timers for precise documentation and dose control.

The radiant head pivots 0–180° and the column extends from 850 mm to 1640 mm, so the unit pairs with any infant incubator, radiant warmer or baby cradle. Fanless design (no noise) keeps the newborn calm during treatment. Four braked castors on an aluminum-alloy + steel base keep the unit mobile and stable.

Especificações

Construída em padrões neonatais.

ModelPCB-FL-01
ConfiguraçãoUnidade LED de fototerapia móvel · suporte de piso
Elementos radiantes17 × Lâmpadas LED azuis
Comprimento de onda420 – 490 nm
Vida útil LED50,000 hours
Graus de intensidade3 níveis ajustáveis: Baixo / Médio / Alto
Irradiância total (Alto)4,500 μW/cm² · 75 μW/cm²/nm
Irradiância total (Médio)3,200 μW/cm² · 53 μW/cm²/nm
Irradiância total (Baixo)1,450 μW/cm² · 24 μW/cm²/nm
Área superficial efetiva400 × 300 mm (medida a 360 mm)
Tamanho do cabeçote380 × 220 mm
Faixa de altura ajustável850 mm – 1,640 mm
Ângulo do cabeçote0 – 180°
TelaLCD · tempo de terapia + tempo integral (separados)
Modos de timerCuenta crescente + Cuenta regressiva
Faixa timer regressivo30 min – 48 h
Faixa tempo integral0 – 99,999.9 h
Precisão de tempo1 min / 12 h
Nível de ruídoSem ventilador · operação silenciosa
BaseAlumínio + aço · 4 rodízios com freio
AlimentaçãoAC 110 – 240 V · 50 / 60 Hz
Potência60 VA
Temperatura operacional+18 °C to +30 °C
Umidade operacional30 – 75 %
Pressão operacional700 – 1060 hPa
Temperatura de armazenamento−10 °C to +55 °C
Umidade de armazenamento≤ 95 %
Pressão armazenamento500 – 1060 hPa
Tamanho embalagem94 × 58 × 18 cm · N.W. 10 kg · G.W. 12.6 kg
CertificaçõesCE 0197 · ISO 13485:2016 · TÜV Rheinland
Recursos principais

Projetada para tratamento de icterícia neonatal.

17 × Lâmpadas LED azuis

Bank of 17 high-intensity blue LEDs at 420–490 nm — the clinically optimal wavelength for converting bilirubin. 50,000-hour service life vs only ~2,000 hours for traditional fluorescent tubes.

Intensidade 3 níveis (Baixo / Médio / Alto)

Adjustable irradiance from 1,450 to 4,500 μW/cm² — match the dose to the clinical protocol and bilirubin level. High mode delivers intensive phototherapy.

Distribuição uniforme de luz

Uniform high-intensity light across the effective surface area (400 × 300 mm at 360 mm) — every part of the newborn’s exposed skin receives consistent dose.

Tela LCD + timers duplos

LCD shows therapy time and integral time separately. Count-up for documentation, count-down (30 min – 48 h) for protocol-driven dosing. Faixa tempo integral up to 99,999 h.

Sem ventilador · operação silenciosa

LED design produces minimal heat — no cooling fan needed. Zero fan noise, no air movement near the newborn, no infection-control concerns from fan blade dust.

Cabeçote + altura ajustáveis

Radiant head pivots 0–180°, column adjusts from 850 to 1,640 mm — pairs with any incubator, radiant warmer or baby cradle. Optimal positioning for every clinical setup.

Base móvel estável

Aluminum-alloy + steel support base with 4 castors with brake — easy to move between rooms, locks securely in place during treatment.

LED de longa duração

50,000-hour Vida útil LED means 5+ years of continuous use at typical clinical duty cycles. Far lower lifecycle cost than fluorescent or halogen alternatives.

Compatível com

Combina com qualquer unidade de cuidado aberto ou fechado.

Incubadora Neonatal

Position the radiant head above any closed incubator — PCB-INC-10 / 20 / 30 or any standard incubator. Adjustable height + angle.

Berço Aquecido Radiante

Pairs with open-care radiant warmers (PCB-IRW-10 / 20) for combined warming + phototherapy treatment.

Berço

Use over any newborn cradle, bassinet or nursery bed. Mobile design moves between cribs as needed.

Berçário

Treat multiple newborns in the well-baby nursery — move the unit between cribs throughout the shift.

Aplicações
Icterícia Neonatal Hiperbilirrubinemia UTIN Berçário Recuperação Neonatal Alas Pediátricas Maternidades Cuidado Domiciliar (aluguel)
Qualidade certificada

Fabricado sob ISO 13485:2016

The PCB-FL-01 is manufactured under ISO 13485:2016 · TÜV Rheinland certification, with CE 0197 mark for the European market. Every unit passes a full safety + functional test before shipping, ensuring compliance with regulatory requirements in every market.

✓ CE 0197
✓ ISO 13485:2016
✓ TÜV Rheinland
📄

Folheto do produto

Complete PCB-FL-01 data sheet in PDF, ready to print or send to your customer.

Baixar folheto (PDF) ↓

Formato PDF · Português

PCB Medical · Kentucky (USA)

10342 Bluegrass Pkwy

Louisville, KY 40299

PCB Medical · China

2103 Citic Tower, 1500 Xiangjiang North Road

Changsha, China

© 2026 PCB Medical Equipment

Reviews

There are no reviews yet.

Be the first to review “PCB-FL-01”

Your email address will not be published. Required fields are marked *

WhatsApp